政大機構典藏-National Chengchi University Institutional Repository(NCCUR):Item 140.119/133661
English  |  正體中文  |  简体中文  |  Post-Print筆數 : 27 |  Items with full text/Total items : 109952/140903 (78%)
Visitors : 46029505      Online Users : 781
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    Please use this identifier to cite or link to this item: https://nccur.lib.nccu.edu.tw/handle/140.119/133661


    Title: Tumor phase recognition using cone‐beam computed tomography projections and external surrogate information
    Authors: 洪英超
    Hung, Y.C.
    Tsai, P.F.;Yan, G.;Liu, C.;Kahler, D. L.;Park, J.Y.;Potter, N.;Li, J.G.;Lu, B.
    Contributors: 統計系
    Keywords: lung;tumor phase recognition;principal component analysis;singular;spectrum;analysis;gating
    Date: 2020-05
    Issue Date: 2021-01-22 09:16:15 (UTC+8)
    Abstract: Purpose: Directly extracting the respiratory phase pattern of the tumor using cone-beam computed tomography (CBCT) projections is challenging due to the poor tumor visibility caused by the obstruction of multiple anatomic structures on the beams-eye view. Predicting tumor phase information using external surrogate also has intrinsic difficulties as the phase patterns between surrogates and tumors are not necessary to be congruent. In this work, we developed an algorithm to accurately recover the primary oscillation components of tumor motion using the combined information from both CBCT projections and external surrogates. Methods: The algorithm involved two steps. First, a preliminary tumor phase pattern was acquired by applying local principal component analysis (LPCA) on the cropped Amsterdam Shroud (AS) images. In this step, only the cropped image of the tumor region was used to extract the tumor phase pattern in order to minimize the impact of pattern recognition from other anatomic structures. Second, by performing multivariate singular spectrum analysis (MSSA) on the combined information containing both external surrogate signal and the original waveform acquired in the first step, the primary component of the tumor phase oscillation was recovered. For the phantom study, a QUASAR respiratory motion phantom with a removable tumor-simulator insert was employed to acquire CBCT projection images. A comparison between LPCA only and our method was assessed by power spectrum analysis. Also, the motion pattern was simulated under the phase shift or various amplitudes conditions to examine the robustness of our method. Finally, anatomic obstruction scenarios were simulated by attaching a heart model, PVC tubes, and RANDO® phantom slabs to the phantom, respectively. Each scenario was tested with five real-patient breathing patterns to mimic real clinical situations. For the patient study, eight patients with various tumor locations were selected. The performance of our method was then evaluated by comparing the reference waveform with the extracted signal for overall phase discrepancy, expiration phase discrepancy, peak, and valley accuracy. Results: In tests of phase shifts and amplitude variations, the overall peak and valley accuracy was -0.009± 0.18 seconds, and no time delay was found compared to the reference. In anatomical obstruction tests, the extracted signal had 1.6± 1.2 % expiration phase discrepancy, -0.12±0.28 second peak accuracy, and 0.01±0.15 second valley accuracy. For patient studies, the extracted signal using our method had -1.05±3.0 % overall phase discrepancy, -1.55±1.45% expiration phase discrepancy, 0.04±0.13 seconds peak accuracy, and -0.01±0.15 seconds valley accuracy, compared to the reference waveforms. Conclusions: An innovative method capable of accurately recognizing tumor phase information was developed. With the aid of extra information from the external surrogate, an improvement in prediction accuracy, as compared with traditional statistical methods, was obtained. It enables us to employ it as the ground truth for 4D-CBCT reconstruction, gating treatment, and other clinic implementations that require accurate tumor phase information.
    Relation: Medical Physics, 47:10, 5077-5089
    Data Type: article
    DOI link: https://doi.org/10.1002/mp.14298
    DOI: 10.1002/mp.14298
    Appears in Collections:[Department of Statistics] Periodical Articles

    Files in This Item:

    File Description SizeFormat
    90.pdf2714KbAdobe PDF2172View/Open


    All items in 政大典藏 are protected by copyright, with all rights reserved.


    社群 sharing

    著作權政策宣告 Copyright Announcement
    1.本網站之數位內容為國立政治大學所收錄之機構典藏,無償提供學術研究與公眾教育等公益性使用,惟仍請適度,合理使用本網站之內容,以尊重著作權人之權益。商業上之利用,則請先取得著作權人之授權。
    The digital content of this website is part of National Chengchi University Institutional Repository. It provides free access to academic research and public education for non-commercial use. Please utilize it in a proper and reasonable manner and respect the rights of copyright owners. For commercial use, please obtain authorization from the copyright owner in advance.

    2.本網站之製作,已盡力防止侵害著作權人之權益,如仍發現本網站之數位內容有侵害著作權人權益情事者,請權利人通知本網站維護人員(nccur@nccu.edu.tw),維護人員將立即採取移除該數位著作等補救措施。
    NCCU Institutional Repository is made to protect the interests of copyright owners. If you believe that any material on the website infringes copyright, please contact our staff(nccur@nccu.edu.tw). We will remove the work from the repository and investigate your claim.
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback